Plumber's Classic 1/2 HP Cast Iron Submersible Sump Pump
IN U.S.A. SIM534 (Rev. 10/27/03) OWNER'S MANUAL Plumber's Classic 1/2 HP Cast Iron Submersible Sump Pump 293 Amps Motor Full Load (maximum)..12.0 Amps Discharge Pipe Size..1–1/2" NPT PERFORMANCE INSTALLATION 1. Install the pump in a sump pit … Access Full Source
Harbor Freight 1 HP Electric Water pump. – YouTube
Harbor Freight 1 HP electric Water pump. And if it was pulling that much at startup, it would trip the 20 amp breakers in my house in an instant- thats 109 amps. … View Video
Zoeller 915 Grinder System – YouTube
Industry first, 1/2 HP, 115 volt grinder pump. 7 amps. Greatly reduces initial cost of grinder systems and annual operating costs compared to traditional 2 H 1:05 Watch Later Error Sump Pump Working Hard by ccruzer65 979 views; 1:53 Watch Later Error Part 2 of the sewage ejector … View Video
DUAL Car Audio Batteries W/ 1000 Amps – Deep Cycle SPL Stereo …
2 C&D Liberty 1000's – 200lbs of pure Cold Cranking Madness! 1000 AMPS / 2.5kw (1) Alpine MRP 500 – Class D Monoblock Amplifier (1) Alpine MRP 1000 – Class D Monoblock Amplifier (3) 12 inch Orion HP Subs – 500 Watts @ 2 ohms … View Video
118-5 SYSTEM Sump Pump Hide-Away Basin System (14.5" W, 16" H …
Pump/Motor Unit Submersible Automatic Models BV-A1 Horsepower 1/4 Full Load Amps 6.5 (Not Included) 1–1/2" Dia. Hole Inlet Opening Dimensional Data 118-5 Sump Pump Hide-Away Basin System … Return Document
1/3 And 1/2 HP Submersible Sump Pump
Canada * www.saveonpumps. com * Tel: (604) 828-9336 1/3 and 1/2 HP Submersible Sump Pump * Reinforced thermoplastic housing, volute and Flow Rate (GPH) Weight (lb.) Hz Amps XKS-552PW 1/3 1 1/16" 95ºF 17' 2,700 11.0 60 4.5 XKS-752PW 1/2 1 1/16" 95ºF 23' 2,800 13.2 60 5.5 Performance Performance Performance … Read Content
IRONMATE®1/2 HP Cast Iron Submersible Sump Pump
Web Site: http://www.flotecwater.com OWNER'S MANUAL IRONMATE ® 1/2 HP Cast Iron Submersible Sump Pump NOTICE Amps Motor Full Load (maximum)..12.0 Amps Discharge Pipe Size..1–1/2" NPT PERFORMANCE INSTALLATION 1. Install the pump in a sump pit … Fetch Document
Electrical Wire Sizes – What Size Electrical Wire Do I Need
15 Amps: 14 Gauge: Receptacles, 110-volt Air Conditioners, Sump Pumps, Kitchen Appliances 2 Gauge: Service Entrance: 150 Amps: 1/0 Gauge: Service Entrance: 200 Amps: 2/0 Gauge … Read Article
Protect Your Home
Watchdog pumps use substantially fewer amps, making them considerably less expensive to run. Average cost savings earned when using a BW1033 1/3 HP sump pump is $60.44 per year, $63.47 per year when using a BW1050 1/2 HP sump pump.** … Read Content
Chiller – Wikipedia, The Free Encyclopedia
Chilled water temperatures can range from 35 to 45 degrees Fahrenheit (1.5 to 7 degrees Celsius and hence the chiller cooling capacity is measured in kilowatts input (kW), Horse Power input (HP less common open loop industrial chillers control the temperature of a liquid in an open tank or sump … Read Article
SUBMERSIBLE SUMP PUMPS
R5S-1 1/2 HP MODEL R3S 1/3 HP EASTERN STANDARD CONSUMER HOT-LINE: 1-800-942-3343 of 15 amps. NEVER touch the pump when it is con-nected to electrical power. 1. for 1–1/4" and 1–1/2" pipe. Sump basin 14" to 18" in diameter … Doc Viewer
SP-330 SP-330D SP-500 SP-500A Submersible Sump Pumps OPERATOR …
Ridge Tool Company SP-330, SP-330D, SP-500, SP-500A Submersible Sump Pumps 4 Specifications Motor: Type..Shaded Pole Rating..120V, Single Phase 1/3 HP, 9.5 Amps 1/2 HP, 10 Amps Pump … Retrieve Here
What Is A Battery Backup? (UPS, Uninterruptible Power Supply)
A battery backup is a device that helps provides consistent power to a computer system. A battery backup can also be called an uninterruptible power supply, or UPS. … Read Article
Which PSP? How To Choose The PSP That's Best For You
Whether you're looking to buy a PSP for yourself, or as a gift for someone else, you'll want to make sure to buy the right model. Though the differences between models aren't huge, they can be significant depending on the intended use of the PSP. … Read Article
Generator Power Application Guide
Page 2 ADDITIONAL TOOL OR STARTING RUNNING STARTING APPLIANCE WATTS WATTS WATTS 1. Refrigerator 2,200 700 1,500 2. Sump Pump 1,300 800 500 3. Single-Phase Induction Motor Starting Requirements Motor Start Code GH J K LMNP KVA/HP 6.3 7.1 8.0 9.0 10.0 11.2 12.5 14.0 VOLTS AMPS HP 230 2.5 1/4 Hz PHASE CODE 60 1 M … Fetch Doc
Keen Pump SS3
Revised 6-9-2008 Models Available Model No. HP Volts Operation Float Type Cord Solids Weight S33A 1/3 115 Automatic Wide Angle 20' ¼" 18 lbs S33M 1/3 115 Manual None 20' ¼" 18 lbs High Efficiency Motor: 3.5 Run Amps 2–1 Keen Pump SS3 Stainless Steel 1/3 HP Sump Pump All stainless steel … Get Content Here
Pump Specifications ELV Series Submersible Sump Pump With …
hp. voltage: phase. full load amps: locked rotor amps: thermal overload temp. stator winding class: cord length ft. discharge: automatic. elv290: 3/4. 115: 1. 10.4: 24. 120˚c/ 248˚f … Fetch Document
1/2 hp Automatic Submersible Sump Pump
1/2 hp Automatic Submersible Sump Pump SS-50-A Series Features ■Cast iron pump housing with protective epoxy HP VOLTS DISCHARGE SIZE RUNNING AMPS/WATTS PERFORMANCE (GPM) SHUT-OFF CORD … View Full Source
Conserving Electrical Energy … One Sump Pump At A Time
The amount of electrical energy consumed by a sump pump depends on: 1. the Horsepower (HP) rating of the pump; 2. For example, a 1/3 HP sump pump with a split-phase motor requires 9.7 Amps. at 115 VAC, while a 1/3 HP sump pump with a PSC motor only … Retrieve Content