CONSTRUCTION METHODS For STANDING COLUMN WELLS
TYPICAL SCW SCHEMATIC S S Supply Lines Recycle Lines All Under Ground Pipe is See Detail for Heat Pump 20-60 ft z S S in Pit in NE Rear Corner Located in Sub Cellar Pit Drain to Central Sump Pit w/ Sump Pump by Flow Meters Back Pressure Regulators See Drawing VSD-5HP-5 for VSD Well Pump Controls See Dwg: VSD-5HP … Document Viewer

Amend 003 (2)
detail 4 for the Equal basin Class II road section neither show a thickness of the Class II. will be same as Tertiary Sump Pump (P-31-750) as specified in Specification Section containing the following document files: 1) Bid Set Drawings (dwg); 2) Updated TOC … Retrieve Content

Adopted August 23, 2006
All elevator pits shall be provided with a sump pump. The sump pump shall be hard piped and hard wired and equipped with a hose Curb modifications for wheel chair ramps and crosswalks (P.W. Dwg. No. 02775-04) , . 5c. Commercial curb ramp detail (P.W. Dwg. No. 02775-05). … View Full Source

OFM Pump, Inc. P.O. Box 12192 Odessa, TX 79763
Installation detail for ofm dia. installation detail gear ratio 6.353 : 1 ofm pump , inc. 61 1 oil sump " o" ring 2 pipe plug , 1/2" npt size dwg number e 1 : 2 ofm pump , inc. item no. … Content Retrieval

Location Requirements For Natural Gas Installations
Clear 8' path from the gas main to the service entrance • 2 psi delivery pressure • Developer is responsible for all restoration • Clearly mark the location of all private underground facilities 1 such as (but not limited to): – Sewer lines – Septic systems – Invisible fences – Sump pump extensions … Fetch This Document
Basement Waterproofing – Wikipedia, The Free Encyclopedia
A proper sump pump, backup sump and/or battery backup sump pump should be installed in a large sump pit with an airtight lid for safety and to keep humidity from seeping through to the basement environment, where it can promote mold growth. … Read Article

City Of Winchester
Electrical panel detail. 3. Pump and alarm control elevations. 4. Finished grade and foundation elevations. files shall be presented in AutoCAD format, either *.dwg … Return Document

9200 Condensate Trap, Built By Jay R. Smith Mfg. Co.
5 (125) OPTIONAL MATERIALS: Polished Chrome Plated Cast Bronze P-Trap -CP 9200 9200 CM WH JM 9-6-85 NONE S9200 N *A Slip Joint Nut and Seal 1/8 (3) B C D Condensate Connection 12 (305) MAX 4 1/4 (110) Wall Tube 1 1/2" (38) Female NPT Connection Ground Joint Elbow Escutcheon Finished Wall K 5-19-94 Add Var, Rev Table, Chg Dwg EMB … Fetch Content

SECTION 6: WASTEWATER PUMP STATION
Special provisions may supplement the Standard Specifications and may specify in detail the construction of sewer, wastewater pump station, and all appurtenances. 6.04 Sump Pump Piping: All sump pump fixed piping in wetwells shall be schedule 80 PVC and in dry wells shall be brass. … Access Document

Chem Waste Kettleman Closure Plan Appendices Vol 1 Of 7
LCRS Sump-The system currently has a 50 gallon-per-minute (gpm) sump pump that is required The flow of leachate in the waste and LCRS is discussed in more detail in the LCRS calculations in E^ilcsFramCljanb\Kettleman\l0-23-06 Blorwetor Drawing$ from Shar\nGURE 9 PRCCESSRI MODl~ED.dwg … Get Content Here

INDEX OF STANDARD DRAWINGS
Std. 205 trench detail . std. 206.3 shovel slicing of haunching material std. 213.1 sump pump connection . std. 215 pipe underdrain . std. 216 low flow storm sewer … Fetch Full Source

Premier™ Cooling Tower
• For the typical wiring schematic of fan motor and tower accessories, see Delta dwg. Low water level in sump causing air to be drawn into pump and piping. 3. Improper selection of water circulating pump. … Fetch Doc

. 6 – HP/V/ph ELECTRICAL SSC-27 GSW 29.8 -0.33/115/1 3.0m …
details and schedules se09-001m8-1.dwg 1:125 drawing no.: thermostat equivalent to carrier each furnace shall be complete with: 3 elevator sump pit detail n.t.s base 150mm thick float in conduit high level alarm outlet to electrical sump pump p-1 submersible … Get Doc