Amendment Of Contract V514C-496 Page 2
Answer: The design intent for this project is to use PVC Schedule 40 Conduit for concrete encasement in duct banks; PVC conduit fittings for use with Answer: The design for the sump pump systems includes the following: ½ hp heavy duty sump pump, 115Vac, 9.7Amps, 10gpm @ 15 feet total dynamic … Fetch Document
SPECIAL PROVISIONS – SEWER & WATERMAIN RECONSTRUCTION STH 47 …
Where proposed storm laterals are to be connected to existing sump pump lines concrete encasement will be paid at twice the bid price for lateral reconnection. … Fetch This Document
ICC INTERNATIONAL PLUMBING CODE, 2003 Edition Table Of Contents
Sump Pump discharge 24. Downspouts 25. Separation between Sewer and Water lines After the saddle connection has been made, encasement in six (6) inches of concrete may be required to provide a secure and watertight connection, … Access Content
UNDERGROUND DUCT SYSTEM (GREATER THAN 600 VOLT)
Provide lighting and sump pump in each manhole Manhole cover to be either round or hinged. 2.6 Where PVC is used, ductbank conduit run shall PERFORMANCE STANDARDS: 3.1 Install all ductbanks with red concrete encasement. … Access Content
SUBJECT: Policy For The Design, Construction, Permit …
Concrete encasement in accordance with the Regional Standard Drawing S-7 is required for a sewer lateral with a cover less than 4 feet deep from invert Sump Pump: For properties lower than the sewer main, sump pumps shall be installed in accordance with the City's Plumbing Code. … Access Document
SECTION TABLE OF CONTENTS DIVISION 16 – ELECTRICAL SECTION …
PHASE VI UTILIDORS, EIELSON AFB, AK EIE210 (3) A single receptacle with weatherproof cover shall be provided for power connection of sump pump. Provide new equipment and materials. 3.2.1 Installation Underground 3.2.1.1 Underground Conduit/Duct without Concrete Encasement The type of conduit … Document Viewer
FACILITY STORM DRAINAGE PIPING
Install encasement on piping according to ASTM A 674 or AWWA C105. Retain paragraph and subparagraph below if ductile-iron, force-main piping is B. Shutoff Valves: Install shutoff valve on each sump pump discharge. 1. Install full-port ball valve for piping NPS 2 (DN 50) and smaller. … Content Retrieval
How To Replace Windows : How To Remove Old Windows – YouTube
Learn how to remove old windows from a window installation engineer in this free video on remodeling your house. Expert: Dave Belch Bio: After working for his father, Dave … View Video
Henry C. Garnett Water Purificaiton Plant Expansion Project …
Complete concrete encasement of 72" raw water pipe and install headwall in the north pond. Completed sump pump installation and testing. Completed HVAC installation and testing. … View Document
Shopping – YouTube
Http://bandmerch.seenon.com/detail.php?p=74212 http://www.hotforwords.com to request words Origin of the word shopping … View Video
017
encasement canal 10" water main 6' high c/l fence 50' x 50' easement 10" water main underground telephone cable sump pump w/ 2" waste trench drain w/ 4" waste compactor exit exit generator transformer … Fetch Doc
Sitesubplans.townofcary.org
encasement ramp sump pump shall located and at 3,000 p.s access door cast into a ' operated in the vault, prop osed slab and meet h-20 loading … Content Retrieval
BEAUFORT-JASPER WATER & SEWER AUTHORITY
Encasement Pipe: Encasement Pipe installed by boring and jacking shall be welded steel pipe conforming to ASTM A139, Grade B, 35,000 PSI minimum yield All vaults, pits, etc. shall be sealed or provided with an approved sump pump. … Content Retrieval
CON U2-15.1, Installation Of Ring Type Vaults
Concrete Encasement"; Construction Guideline; SCL U2-11; "Installation of Nonmetallic Conduit with Concrete, FTB Encasement"; Construction Standard; SCL U2-12.1/NVH-60; "Sump Pump Pipe Installation, … Read Document
WEBSTER CITY, IOWA
A smooth, neat joint shall be made, and the connection made secure and watertight by encasement in concrete. Special fittings may be used for the connection only when approved by the City. … Get Document
Section 26 05 41 – Underground Electrical Construction
Include sump pump circuit in manholes subject to flooding. Show circuits on plans. Use vibrators when this portion of the encasement is poured to ensure a seal between the envelope and the wall of the structure. … Doc Retrieval
Pressure Regulating Station No. 69
Plug valves, pressure regulating valves, ladder, sump pump, pipe supports, Furnish and install concrete encasement saddle support as per Detail on Sheet 9 of the … Return Doc